Data Storage Systems, Inc. offers the full line of QLogic fibre channel
solutions including the QLogic SANbox 9000 Stackable Fibre Channel Switch.
Along with all the QLogic fibre channel products, DSS, Inc. offers
implementation/integration services if needed. For further information and
assistance, please call our sales department at (763) 416-0474.
The QLogic SANbox 9000 Stackable Switch is the perfect enterprise level
fibre channel switch for all the right reasons. Scalability is the key feature of
the QLogic SANbox 9000. FT & HyperStack™ & Call-Home Now Available!
SANbox 9000 now becomes a true Director-class switch with the addition of
the new FT CPU Failover, HyperStack and Call-Home features. Reduce TCO
with the industry’s first Customer Replaceable Unit (CRU) components,
smallest footprint, most flexible rack-mount options and leading
power/cooling efficiency.
Finally, there’s a new class of core switch that represents a sane alternative to quarter million dollar Director switches. The QLogic
SANbox 9000 series is designed to the core for cost sensitive, business-critical, open system environments that require a ultra-high
density, blazing performance, 99.999% availability, intelligent, switch platform for their data center core. SANbox 9000 series
represents a number of industry firsts: a stackable chassis for simple, cost-effective scalability, a 4U chassis for smaller footprint,
the simplicity and economies of Customer Replaceable Units (CRUs) and a comprehensive set of core switch software management
tools included as standard. Best of all, pricing starts at under $100K.
The highly scalable QLogic SANbox 9000 is a stackable chassis switch with a dedicated 800Gb/s HyperStack connection between as
many as two chassis modules. The high port count SANbox 9000 supports up to 256 ports in a dual chassis configuration. The
intelligent SANbox 9000 offers in one chassis module: 8 slots for any mix of 4Gb or 10Gb Fibre Channel I/O Blades, iSCSI Intelligent
Storage Router I/O Blades, FCIP Intelligent Storage Router I/O Blades, or Storage Services Platform (SSP) Blades. For high
availability, the SANbox 9000 features redundant, hot-swap I/O, SSP, CPU, Power Supply and Fan blades. And for comprehensive
fabric management, the SANbox 9000 includes a powerful and easy-to-use suite of software tools for setting-up, monitoring,
tuning, troubleshooting and servicing an unlimited number of large fabrics.
For configuration options, pricing and availability please allow DSS, Inc. to put together a detailed solution designed to meet your
project criteria and earn your business.
At twice the port density of typical 14U Director switches, the SANbox 9000 stackable chassis switch scales to 128 ports in a 4U single chassis module or
up to 256 ports in an 8U dual chassis module HyperStack configuration (via backplane interconnects) 32 ports per 1U of rack space!
Unlike legacy Director switches, the SANbox 9000 switch provides a low cost entry point with a 16 4Gb FC port configuration.
Seamlessly grow your 9000 switch in 16 port increments up to 256 ports
Eight I/O Blade slots per chassis module supporting multi-protocol and multi-function technologies including:
-4Gb FC I/O Blade: for maximum server and storage connectivity.
-10Gb FC I/O Blade: high-speed Inter-Switch Links (ISLs) including trunking between other Core, Distribution and Edge class switches.
Intelligent Storage Router Blade: iSCSI for connecting low cost servers and FCIP for replicating data across a WAN
Storage services Platform SSP Blade: pool heterogeneous storage
Broadly deployable in local, campus, distributed and remote Core/Distribution/Edge configuration topologies.
ENTRY Model SB9100 fully upgradeable in the field to single or dual HyperStack BASE Model SB9200
BLAZING PERFORMANCE Non-blocking, full-duplex bandwidth at 800Gbps in a single chassis module or a massive 1.6TBps for a dual module HyperStack
configuration (64 10Gb or 256 4Gb FC ports) to enable high Performance Computing, Video and Satellite Capture data streaming
applications.
Industry’s lowest latency and No-Wait routing for maximum transaction performance via powerful embedded CPU and I/O ASICs.
CUSTOMER REPLACEABLE UNITS (CRUs) The industry’s first stackable chassis switch designed for the convenience, simplicity and economies of Customer Replaceable
Units (CRUs) for key components.
99.999% availability with redundant, hot-pluggable CPU, Power Supply, Fan and I/O Blades, non-disruptive code load and
activation (NDCLA) and non-disruptive CPU failover in support of 24x7 mission-critical operations.
LOW TOTAL COST OF OWNERSHIP All the benefits of a Director Class switch with revolutionary pricing that starts under $100K.
Architected for long-term investment flexibility and protection to deliver a previously unachievable reduction in total Cost of
Ownership (TCO).
For SAN administrators that have invested in multi-vendor fabrics, the SANbox 9000 is interoperable with all FC-SW-2 compliant
Fibre Channel Director, Edge class switches and popular servers, storage and networking products from major manufacturers.
Minimize management costs with easy-to-use and comprehensive Command Line Interface (CLI), QuickTools embedded web
interface, and Enterprise Fabric Suite 2007 software tools included with each SANbox 9000 switch.
QLogic 9000 Series is designed to be highly scalable for business critical open system environments
Features and Benefits:
SB9100-00A-E
Single CPU blade installed. Front-to-back airflow.
Includes installed firmware, printed Quick Start
Guide, warranty card, CD containing QLogic
software management applications (CLI,
QuickTools, Enterprise Fabric Suite and Fabric
Security Package). 1Yr STD Warranty.
$24,199.00
SB9100-00B
Single CPU blade installed. Back-to-front airflow.
Includes installed firmware, printed Quick Start
Guide, warranty card, CD containing QLogic software
management applications (CLI, QuickTools,
Enterprise Fabric Suite and Fabric Security Package).
$24,199.00
SB9200-00A-E
Dual redundant CPU blades installed. Front-to-back
airflow. Includes installed firmware, printed Quick
Start Guide, warranty card, CD containing QLogic
software management applications (CLI, QuickTools,
Enterprise Fabric Suite and Fabric Security Package).
$34,030.00
SB9200-00B
Dual redundant CPU blades installed. Back-to-front
airflow. Includes installed firmware, printed Quick Start
Guide, warranty card, CD containing QLogic software
management applications (CLI, QuickTools, Enterprise
Fabric Suite and Fabric Security Package).
$34,030.00
Both QLogic 9100 entry and 9200 base models include a one-year hardware/firmware warranty with one-year of Preferred
service (remote technical phone support 7 days a week, 24 hours a day, and next-business-day spare advanced replacement).
Software license key for SANdoctor Diagnostics, sold on a per-switch basis.
Fault Tolerant CPU Failover software license key for QLogic SB9200 base model only.
HyperStack feature software license key for SB9200 base model only, sold per chassis module. Includes two
yperStack cables per license.
16-port 4/2/1Gb Fibre Channel I/O Blade.
4-port 10Gb Fibre Channel I/O Blade (X2 form factor).
SB9100 entry to SB9200 base model CPU Upgrade.
Single power supply blade - front to back airflow.
Single power supply blade - back to front airflow.
Single fan blade - front to back airflow.
Spare: Single fan blade - back to front airflow.
Spare: I/O blade slot blank.
Spare: CPU blade blank (SB9100 entry model only).
Spare: Chassis module, including maintenance panel.
Spare: 4U Chassis Module Rail/Racking Kit for standard or reverse racking.
Spare: Single CPU Blade.
Spare: Single HyperStack cable - length = 25" (635mm).
X2-XPAK-COPP-78 X2 to XPAK 10Gb Fibre Channel ISL cable (copper) - length = 78" (2m).
X2-XPAK-COPP-18 X2 to XPAK 10Gb Fibre Channel ISL cable (copper) - length = 18" (456mm).
X2 to X2 10Gb Fibre Channel ISL cable (copper) - length = 18" (456mm).
X2-COPP-78 X2 to X2 10Gb Fibre Channel ISL cable (copper) - length = 78" (2m).
X2-SW-01 10Gb (quantity 1) short-wave, 850nm X2 optic transceiver with SC connector.
X2-LW-01 10Gb (quantity 1) long-wave, 1310nm X2 optic transceiver with SC connector.
Optical SFPs - 2Gb (8-pack) short wave SFP connectors.
Optical SFPs - 2Gb (quantity 1) long wave SFP connectors.
Optical SFPs - 4Gb (4-pack) short wave SFP connectors.
Spare: Country Power Kit (dual 2.5m cords): United States Non-Locking NEMA 5-15 Plug (included as standard
with all SB9000s)
Fibre Channel Classes of Service Class 2, Class 3, and Class F (inter-switch frames) connectionless Fibre
Channel protocol support
Modes of Operation Fabric
Public loop
Broadcast
Performance Features
Fabric Port Speed FC4G16 I/O Blades @ 1.0625, 2.2125, & 4.250 Gbps
Auto-sensing of 1, 2, & 4 Gbps port speeds
Optionally programmable to fixed port speed
FC10G4 I/O Blades @ 12.75 Gbps
FC Fabric Latency (Best Case) <0.6µsec @ 1-Gbps
<0.4µsec @ 2-Gbps
<0.3µsec @ 4-Gbps
<0.2µsec @ 10-Gbps
Cut-through routing
FC Fabric Point-to-Point Bandwidth 212MB/s Full-Duplex on 1Gb ports
424MB/s Full-Duplex on 2Gb ports
850MB/s Full-Duplex on 4Gb ports
2550 MB/s Full-Duplex on 10Gb ports
FC Fabric Aggregate Bandwidth SANbox 9100 Model – 408 Gbps, full duplex
SANbox 9200 Model – 816 Gbps, full duplex
2X SANbox 9200 Model HyperStack – 1.632 T bps, full duplex
Non-blocking HyperStack™ architecture
Maximum Frame Sizes
2148 bytes (2112 byte payload)
In-order delivery assured within OX-ID
Per-port Buffering ASIC-embedded memory (non-shared)
Each port has a guaranteed 16-credit zero wait state buffer for full
performance up to
13km @ 2Gb and 2Km @ 10Gb
Buffer credit donor support via software GUI wizard to extend distance
with full performance
Inter-Switch Link (ISL) Trunking Supports aggregation of up to 128 ISLs in one or more trunks between
multiple switches in any port speed combination and across multiple I/O
Blades 10Gb recommended to maximize number of usable 4/2/1Gb
Server/Storage ports on both SANbox 5000 Series and 9000 Series
switches Switch-On-Exchange (SOE) mode for dynamic ISL trunk load
balancing to maximize throughput Assured in-order delivery of frames in
all multi-switch and multi-ISL trunked configurations Adaptive Trunking
to improve efficiency via optimal routing across multiple trunk groups
Intelligent Path Selection (IPS) on all 10Gbps and 4/2/1Gbps ISL trunk
ports Automatic configuration of ISL trunks including multi-hop paths
between multiple switches Supports all multi-switch fabric topologies
including stack, cascade, cascaded loop, and mesh Adaptive Trunking to
improve efficiency via optimal routing across multiple trunk groups
Up to 239 switches depending on configuration Non-disruptive dynamic
addition of ISLs to an existing trunk High availability with automatic path
failover Interop mode support: McDATA Open Mode, Brocade
interopMode 1, Cisco Open Mode
System Processor 800 MHz PowerPC processor
I/O Blade Processor
400 MHz PowerPC processor
Modular Scalability
Ports Per Chassis Module
16 to 128 FC 4/2/1 Gbps ports
4 to 32 FC 10 Gbps ports
Full Blade intermix support, maximum 8 Blades, all Blades hot-pluggable
>475,000 user ports depending on configuration
Ports Per Rack Up to 1,280 ports per 42U rack
Chassis Module HyperStack Two BASE Model SB9200 chassis modules via 4 proprietary HyperStack
cables
Two domains
Up to 256 Fibre Channel 4/2/1 Gbps ports
Multi-switch Fabrics Supports all topologies, including: stack, cascade, cascaded loop, and
mesh
Maximum 239 switches (domain IDs) depending on configuration
Fabric Port Types All ports are universal, auto-discovering, self configuring and can
assume the following states:
F_Port: Fabric (N_Port Id Virtualization [NPIV] support automatically
enabled) with up to
255 NPIVs per port
FL_Port: Fabric loop (public loop)
E_Port: Switch-to-switch
Administrative Port Types G_Port: Generic
GL_Port: Generic loop
Port Security Port binding via list of WWNs (up to 32) allowed access to a port
ISL and port authentication via Fibre Channel Security Protocol (FC-SP)
and DH-CHA P
Fabric Security Fabric binding via list of allowed Domain IDs and Switch WWNs
Inter-switch management communication data path encryption
Secure Shell (SSH) for CL
Secure Socket Layer (SSL) for QuickTools, EFS 2007, and SMI-S
Device, Host, and Switch Authentication
Local security database configuration, or
Remote authentication via a RADIUS Server
Additional MS request authentication via FCGS4 CT authentication
Enable/Disable in-band management of switch
Registered State Change Notification (RSCN)
RSCNs are generated per standard (FC-GS, FCFS, FC-SW, etc.)
Delayed to allow consolidation into single RSCN
QLogic IO StreamGuard™ suppresses RSCNs between initiators
Maintainability
Maintenance Strategy Hot-pluggable Customer Replaceable Units (CRUs) per chassis module
SFP & X2 transceivers
I/O Blades (8 maximum, 3 types w/Intermix)
CPU Blades (2 w/Model SB9200, 1 w/Model SB9100)
Power Supply Blades (2)
Fan Blades (2)
Enhanced data integrity on all data paths
Fabric Shortest Path First (FSPF) rerouting around failed links
Integration with Simple Network Management Protocol (SNMP)
managers
Non-disruptive “hot” firmware code load and activation (NDCLA)
Easy configuration, save, and restore
E-Mail Call Home system initiated alarm/fault notification
Maintenance Access Methods Single point in-band management with autodiscovery across multiple
switches via software GUI
One out-of-band Ethernet 10/100Mb BaseT RJ-45 management port
per CPU Blade,
each replicated on Maintenance Panel
One RJ-45 serial port per CPU Blade (RJ-45 to DB-9 conversion dongle
included)
FC-GS4 Management Server
Diagnostics Power-On Self-Test (POST) tests all functional components except SFP
and X2 transceivers
Optional SANdoctor fabric diagnostics software
FC Ping: verifies functional path existence between two ports
FC Trace route: displays path information between a source and
destination
Digital Diagnostics Monitoring: displays real-time SFP, X2, and XPAK
transceiver data
Visual User Interface
LED indicators on the Maintenance Panel, I/O Blades, CPU Blade(s),
Power Supply Blades, and Fan Blades
Maintenance Panel (MP) Dual redundant Maintenance Panel EPROMs maintain chassis-specific
information (such as WWN, SNMP System Object ID, Serial Number,
Part Number, etc.), alternate Ethernet management interface ports,
and LED summary status information for the switch
Global Services Standard 1 year hardware/firmware warranty
SAN Pro Service and Support Programs
SAN Pro Preferred standard on BASE Model SB9200 & ENTRY Model
SB9100:
Next Business Day (NBD) Advanced Delivery spares, 24x7 technical
phone support
Optional: upgrades to SAN Pro Choice (NBD Onsite Replacement) and
SAN Pro Prime
(4-hour Onsite Replacement) available for a fee
For additional information on SANbox 9000 service options, visit:
http://www.qlogic.com/SiteCollectionDocuments/Products/Products_Rig
htNAV_pdf's/Fibre channel switches/SB9000_Service_Opt.pdf
Physical Characteristics Enclosure Chassis Module/Blade Packaging
Standard Rack Mountable Chassis Module
Includes adjustable forward/reverse Mounting Rail/Racking kit & dual
power cords
I/O Blades
Standard and Optional I/O Blades Do NOT Include SFPs, X2
Transceivers, or Copper/Optical
Cables (which you can order separately)
Hardware and Software License Field Upgradeable:
SB9100 ENTRY Model to SB9200 BASE Model
SB9200 Model to SB9200 Fault Tolerant Model
One SB9200 BASE Model to Dual HyperStack Model
Two SB9200 BASE Models to Dual HyperStack Model
Dimensions (chassis module) Width: 431 mm (17.0") 19" rack mountable
Height: 179 mm (7.0") (4U)
Depth: 673 mm (26.5")
Weight (SB9200 chassis module maximum) 40.82 kg (90 lbs)
Power Supply/Cooling (both SB9100 & SB9200) Hot-Pluggable/Dual-Redundant Power Supply Blades with Integrated
Cooling Fans
Dual 7'6" long 3-wire 16AWG power cables with IEC320 input connector
Popular internet and country dual power cable/connector kit options
available
Hot-Pluggable/Dual-Redundant Fan Blades
Back-to-Front and Front-to-Back Airflow Direction Models available
150-cfm airflow
1,000 watts or 3,414 BTU/hour rating per power supply
Heat Output (SB9200 full data traffic maximum) 2,046 BTU/hour at 128-ports 4-Gb Fibre Channel (SFPs and "local
switching")
4,228 BTU/hour at 256-ports 4-Gb Fibre Channel HyperStack (SFPs and
"local switching")
Electrical Requirements Operating Voltage/Frequency
100 to 240 VAC auto-sensing, single phase
47 to 63Hz
Power Source Loading (SB9200 chassis module maximum
power supply rating) 10 Amps at 100 VAC
4.2 Amps at 240 VAC
Operating Load (SB9200 with no data traffic)
550 Watts at 128-ports 4Gb Fibre Channel (including SFPs)
1,120 watts at 256-ports 4-Gb Fibre Channel HyperStack (including
SFPs)
Operating Load (SB9200 with full data traffic) 600 Watts at 128-ports 4Gb Fibre Channel (including SFPs and "local
switching")
1,240 watts at 256-ports 4-Gb Fibre Channel HyperStack (including
SFPs and "local switching")
Circuit Protection
Internally fused
Circuit Protection Internally fused
Environmental Factors Operating
Temperature: 0°C to 40°C (32° to 104°F)
Humidity: 15% to 80% non-condensing
Altitude: 0 to 3048m (0 to 10,000 feet)
Vibration: IEC 68-2, 5-500 Hz, random, 0.21g RMS, 10 minutes
Shock: IEC 68-2: 4g, 11ms, 20 repetitions
Non-Operating Temperature: -40°C to 70°C (-40° to 158 °F)
Humidity: 5% to 90% non-condensing
Altitude: 0 to 15,240m (0 to 50,000 feet)
Vibration: IEC 68-2: 5-500 Hz, random, 2.1g RMS,10 minutes
Shock: IEC 68-2: 30g, 13 msec, trapezoidal pulse
Regulatory Certifications Safety Standards
UL 60950-1 – UL Listed (United States)
CAN/CSA C22.2 No. 60950-1 – cUL Listed (Canada)
EN60950-1 (EC)
CB Scheme-IEC 60950-1 (International)
GOST R (Russia)
Emissions Standards FCC Part 15B Class A (USA)
VCCI Class A ITE (Japan)
ICES-003 Class A ITE (Canada)
EN 55022 Level A (EC)
CISPR 22, Class A (International)
AS/NZS CISPR 22:2002 Class A (AUS/NZ)
GOST R (Russia)
KN22 – Class A (Korea)
Environmental Standards RoHS-5/WEE (EU & Japan)
Voltage Fluctuations EN 61000-3-3
Harmonics EN 61000-3-2
Immunity EN 55024
Marking FCC Part 15, UL (United States)
cUL, CUE, TUV (Canada)
TUV , CUE, CE (EC)
VCCI-A (Japan)
C-Tick (AUS/NZ)
GOST R (Russia)
MIC (Korea)
Exempt (Taiwan)
UL AR/S-Mark (Argentina)
CCC – Field replaceable unit (FRU) power supply modules (China)
Port Statistics Configuration and operational data
Transmitted and received frame counts
Transmitted and received error counts
Media Type (Ordered Separately) Hot-pluggable, industry-standard 3.3 volt SFPs (Small Form Pluggable)
for 4/2/1Gb ports
Hot-pluggable, industry-standard X2 optical transceivers or X2 copper
ISL cables for 10Gb ports
Supported SFP Transceiver Types Short Wave (optical)
Long Wave (optical)
Active/Passive Copper (4/2Gb)
Supported X2 Transceiver Types Short Wave (optical)
Long Wave (optical)
Media Transmission Ranges (@ 10Gbps speeds) Optical Media
Short Wave: 300 m (984 ft.)
Long Wave: 8.34 km (5.18 miles)
Interoperability/Certifications Fully interoperable with all QLogic SANbox switch products
Compatible with FC-SW-2 compliant switches, including Brocade, Cisco
& McDATA
Management interoperability with leading SAN management
applications
FCIA SANmark and SNIA SMI-S certified
SCD-3001v2a1 (E_Port)
SCD-3002v2 (FL_Port)
SCD-3010v1 (RSCN)
SCD-3020v1 (Zoning)
Certified with leading SAN hardware and software vendors.
Visit: http://www.qlogic.com/interoperability/interoperability.aspx/ for
a comprehensive listing
Fabric Services
Software Releases QuickTools version 6.08.02 or later
Enterprise Fabric Suite 2007 version 6.08.02 or later
Switch Firmware version 6.8.03 or later
Ethernet Connections CPU Blade: RJ-45 Ethernet Connector on each CPU Blade on back of
chassis module
Maintenance Panel: Two alternate RJ-45 Ethernet Connectors on
Maintenance Panel on front
of chassis module
Management Methods Enterprise Fabric Suite 2007 Graphical User Interface (GUI)
QuickTools Web Applet
Application Programming Interface (API)
Command Line Interface (CLI)
GS-4 Management Server (including FDMI)
Simple Network Management Protocol (SNMP)
RADIUS
File Transfer Protocol (FTP)
Trivial File Transfer Protocol (TFTP)
Storage Management Initiative (SMI-S)