ATTO Technology FibreConnect 8300 8308 8316 8324 Fibre Channel Switch iU Rackmount



Go Daddy
SecurityMetrics for PCI Compliance, QSA, IDS, Penetration Testing, Forensics, and Vulnerability Assessment
SecurityMetrics for PCI Compliance, QSA, IDS, Penetration Testing, Forensics, and Vulnerability Assessment
Bookmark and Share
McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams
Data Storage Systems, Inc. offers the full line of ATTO Technology fibre channel solutions including the FibreConnect 8300 Series Fibre Channel Switch's. Along with all the ATTO Technology fibre channel products, DSS, Inc. offers full design and implementation/integration services if needed. For further information and assistance, please call our sales department at (763) 416-0474.

The ATTO Technology FibreConnect™ 8300 series of 8Gb/s Fibre Channel switches provide enterprise features and benefits for small to mid-range SANs. The Atto Technolgy FibreConnect 8300 enable high performance and low latency collaborative workflows.
ATTO Technology FibreConnect 8300 FC Switch Datasheet/Specifications
ATTO Technology FibreConnect 8300
Highlights:
FibreBridge 8308, 8316 and 8324
FibreConnect 8300 Series Fibre Channel Switch - 8Gb/s, 8, 16 or 24 FC Ports, 1U Rackmount
Available in 8, 16, or 24-port configurations, ATTO Technology FibreConnect switches are designed for consolidating storage on a SAN, increased productivity and allows for multiple users to more efficiently share media resources.
Superior Workflow Performance
FibreConnect switches provide high-performance connectivity with all ports capable of operating at 2, 4 and 8Gb/s to enable up to 192Gb/s of uncongested throughput. ATTOexclusive latency management features ensure smooth and reliable data transfer on the
SAN, a critical requirement for high-bandwidth video streaming or backup applications. This level of SAN performance provides organizations with improved storage utilzation and enables faster LAN-free backup to increase overall system performance and
productivity.

Increased Efficiency
FibreConnect switches significantly increase performance and functionality for SANs at a reasonable price, combining auto-sensing 2, 4 and 8Gb/s throughput with features that greatly enhance workflow efficiency. Implementing FibreConnect switches into a SAN
allow users to interconnect and share media resources for applications such as video production, editing and post-production. FibreConnect switches are an affordable solution for consolidating storage on a SAN, which increases productivity and streamlines
workflow processes to meet project deadlines.

Advanced Scalability
The FibreConnect family of switches integrate innovative hardware and software features that make it easy to manage and deploy into a wide range of video and IT environments. With powerful and flexible Ports-On-Demand scalability from 8 to 16 or 24 ports in 8-port increments, FibreConnect allows organizations to start small and grow their storage
networks in a non-disruptive manner.

Simplified Management
FibreConnect switches are easy to setup and configure with the Web Tools interface, making switch configuration, deployment and management an easy process. The FibreConnect has self-configuring switch ports that adjust to match device speeds and
allows for firmware updates and error logging to increase overall serviceability.
Complete SAN solution when combined with ATTO’s 8Gb/s Celerity Fibre Channel HBAs
Provides an affordable foundation for small to mid-range SANs
Delivers full 8Gb/s, 1:1 performance for up to 24 ports in a 1U form factor
Web Tools interface simplifies configuration and management
Enables "pay-as-you-grow" Ports On Demand scalability from 8 to 16 or 24 ports
Dual functionality as either a full-fabric SAN switch or as an N_Port ID Virtualization (NPIV)-enabled gateway
Protects existing device investments with auto-sensing 2, 4, and 8Gb/s capabilities
Proven ATTO and Brocade interoperability with leading video and IT infrastructure vendors
Low power consumption
FCSW-8308-D00
FibreConnect™ 8308
Desktop/Rackable Multi-Link Fibre Channel Switch. 8 independent Fibre Channel ports. Includes eight 8Gb/s LC SFP+, Operating system independent , Auto-sensing of 2, 4 and 8Gb/s interface port speed. New with 1 yr RTF Warranty STD.
FCSW-8316-D00
FibreConnect™ 8316
Desktop/Rackable Multi-Link Fibre Channel Switch. 16 independent Fibre Channel ports. Includes sixteen 8Gb/s LC SFP+ Operating system independent Auto-sensing of 2, 4 and 8Gb/s interface port speed. New with 1 yr RTF Warranty STD.
FCSW-8324-D00
FibreConnect™ 8324
Desktop/Rackable Multi-Link Fibre Channel Switch. 24 independent Fibre Channel ports. Includes twenty-four 8Gb/s LC SFP+ Operating system independent
Auto-sensing of 2, 4 and 8Gb/s interface port. New with 1 yr RTF Warranty STD.
Fibre Channel Standards
FC-PH, FC-PH-2, FC-PH-3, FC-GS-2, FC-FLA, FCFG,
FC-SW3

Certified Maximum
Single FOS fabric: 56 domains, 19 hops

Fibre Channel Ports
24 ports in 8-port increments through Ports-on-
Demand licenses at 8,16 and 24 universal (E, F,
M, FL, or N) ports

Performance
Full line-speed switching at:
2.125Gb/s line speed, full duplex
4.25Gb/s line speed, full duplex
8.50Gb/s line speed, full duplex
Auto-sensing of 2, 4, and 8Gb/s port speed
Optionally programmable to fixed port speed
Speed matching between 2, 4, and 8Gb/s

ISL Trunking
Up to 68Gb/s per ISL trunk (8 ports x 8.5Gb/s (line rate))
Exchange-based load balancing across ISLs with
DPS included in Fabric OS

Aggregate Bandwidth
408Gb/s: 24 ports x 8.5Gb/s (line rate) x 2 (full duplex)

Maximum Fabric Latency
700ns with no contention, cut-through routing at 8Gb/s

Maximum Frame Size
2,112-byte payload
Frame Buffers
700 dynamically allocated, 484 maximum per port

Classes of Service
Class 2, Class 3, Class F (Interswitch Frames)

Media Types
Requires FibreConnect hot-pluggable SFP+, LC
connector; Short-Wavelength Laser (SWL);
distance depends on fiber-optic cable and port
speed

Data Traffic Types
Fabric switches supporting unicast, multicast
(255 groups), and broadcast

Port Types
FL_Port, F_Port, M_Port (Mirror Port), and
E_Port; self-discovery based on switch type
(U_Port)
Fabric Services
Simple Name Server (SNS); Registered State
Change Notification (RSCN); NTPv3; Reliable
Commit Service (RCS); Dynamic Path Selection
(DPS); NPIV; N-Port Trunking; FDMI;
Management Server; FSPF; IPoFC, Frame
Redirection; Port Fencing; BB credit recovery

Connectivity Management
Interface
Telnet, HTTP, SNMPv1/v3 (FE MIB, FC
Management MIB); Auditing, Syslog, Change
Management tracking; Web Tools; SMI-S
compliant, SMI-S scripting toolkit

Management Access
10/100 Ethernet (RJ-45), in-band over Fibre
Channel; serial port (RJ-45)

Security
SSL, SSH v2, HTTPS, LDAP, RADIUS, Role-Based
Access Control (RBAC), DHCHAP (between
switches and end devices), Port Binding, Switch
Binding, Secure RPC, Secure Copy (SCP), Trusted
Switch, IPSec, IP Filtering

Diagnostics
POST and embedded online/offline diagnostics,
including RAStrace logging, environmental
monitoring, non-disruptive daemon restart,
FCping and Pathinfo (FC traceroute), port
mirroring (SAN port)

Physical Specifications
Enclosure
Non-port to port-side airflow; 1U; 19-inch EIAcompliant,
power from port side
Includes mounting hardware that will extend
the width to fit a 19h rack

Size
Width: 42.88 cm (16.88 in), Height: 4.29 cm
(24.11 in), Depth: 30.66 cm (12.07 in), System
Weight: 4.2 kg (9.3 lb), without SFP/SFP+ media

Environmental Specifications
Temperature
Operating: 0‹-40‹C (32‹-104‹F)
Non-operating: -25‹-70‹C (-13‹-158‹F)

Relative Humidity
Operating:10% to 85% non-condensing
Non-operational and storage (non-condensing):
10% to 95% non-condensing

Altitude (meters/feet)
Operating: Up to 3,000 meters (9,842 feet)
Storage: Up to 12 kilometers (39,370 feet)

Shock
Operating: 20 G, 6 ms, half-sine
Non-operating: Half-sine, 33 G, 11 ms, 3/eg

Axis
Vibration
. Operating: 0.5 G sine, 0.4 grms random, 5 to 500 Hz
Non-operating: 2.0 G sine, 1.1 grms random, 5 to 500 Hz

Heat Dissipation
Maximum 24 ports: 195 BTU/hr

CO2 Emissions
210 kg per year (with 16 ports at 0.42 kg/kWh)
1.09 kg per Gb/s per year

Input Voltage
85 to 264 VAC nominal

Frequency
47 to 63 Hz

Power Consumption
Nominal 48 watts; maximum 57 watts with 24
ports at 8Gb/s

Regulatory Requirements
United States - Safety: UL60950; EMI: FCC Part 15 Class A
Canada - Safety: CSA No. 60950; EMI: ICES-003 Class A
Australia/New Zealand - EMI: EN550022 Level A
Japan - Safety: IEC 60950; EMI: VCCI Class A
International - Safety: IEC 60950; EMI: CSPR22 Class A
European Community - Safety: EN60950, TUV,
NEMKO; EMI: EN55022 Level A, EN55024
Taiwan - Safety: CNS; EMI: 13438 Class A
© Copyright 2004–2012, Data Storage Systems, Inc.
$3,940.00
$6,406.00
$9,049.00
Contact Us
Data Protection,
Storage Networking Systems.